XMC HDAC30 product photograph
Photo: HDAC30. Configuration and accessory options may differ.

HDAC FRL Combination Units: Two-Piece and Three-Piece

Compare HDAC20–40 three-piece FRL units and HDAC20A–40A two-piece assemblies. Check ports, lubrication flow, drain options and the HDA catalogue before ordering.

  • HDAC: separate filter, regulator and lubricator
  • HDACA: combined filter-regulator plus lubricator
  • 20, 30 and 40 body sizes with model-specific lubrication thresholds

HDAC30 · HDAC30 three-piece combination. Selected specifications are shown below.

21 June 2025 edition · Printed pages 48–59 · 7.3 MB. The PDF contains the original catalogue information, ordering references and available drawings for this series.

Open the 21 June 2025 catalogue

Selected specifications.

HDAC30 · HDAC30 three-piece combination.

Your selected reference will be included in the inquiry. See the product documents for configuration details.

HDAC30 · 21 June 2025 catalogue · Printed page 48
ConfigurationFilter + regulator + lubricator
Port options1/4 or 3/8
Filter element25 µm standard; 5 µm and 50 µm options
Pressure regulating range0.05 to 0.85 MPa
Minimum oil mist flow40 L/min
Maximum working pressure1.0 MPa
Working mediumFiltered compressed air
Ambient and fluid temperature5 to 60 °C
Installation positionVertical, within ±5°

Compare HDAC models.

Swipe to view the full comparison.

HDAC assembly selection · printed pages 48 and 50 · 21 June 2025 catalogue
ModelConfigurationPort optionsMinimum oil mist flow
HDAC20Filter + regulator + lubricator1/8 or 1/415 L/min
HDAC30Filter + regulator + lubricator1/4 or 3/840 L/min
HDAC40Filter + regulator + lubricator3/8 or 1/250 L/min
HDAC20AFilter-regulator + lubricator1/8 or 1/415 L/min
HDAC30AFilter-regulator + lubricator1/4 or 3/840 L/min
HDAC40AFilter-regulator + lubricator3/8 or 1/250 L/min

Choose the assembly around lubrication requirements

HDAC is an FRL assembly for circuits that require filtration, pressure regulation and added oil-mist lubrication. First check the instructions for the downstream valves, cylinders or tools. If they require unlubricated air, select a filter-regulator arrangement without an HDAL lubricator. An FRL assembly does not establish a drying specification, and finer particle filtration does not by itself specify oil-mist removal.

Compare two-piece and three-piece layouts

A three-piece HDAC uses separate HDAF filter, HDAR regulator and HDAL lubricator modules. The A ordering family combines HDAW filtration and regulation in one module, followed by HDAL lubrication. This changes the assembly layout and dimension drawing. Compare mounting width, gauge visibility, pipe alignment and bowl access before choosing the arrangement; do not assume that a two-piece replacement shares the existing bracket locations.

Check working flow as well as connection size

The table distinguishes the 20, 30 and 40 body sizes and their minimum oil-mist flows. Those thresholds describe lubricator operation, not the assembly’s rated supply capacity. Check minimum running flow as well as peak demand, inlet pressure and required outlet pressure. Send the operating conditions with the model inquiry so the selection can be checked against the actual circuit, including intermittent operation.

Specify drainage and plan routine access

Confirm the complete drain, bowl, cover and gauge configuration before fixing the installation. The catalogue distinguishes manual drainage on the 20 body from air-shutoff drainage and an automatic-drain option on larger bodies. Arrange condensate discharge and enough room to inspect and service both bowls. Follow the supplied service instructions for oil filling and maintenance; isolate the supply and release trapped pressure before removing a bowl or component.

View ordering codes and dimension drawings in the HDAC PDF · Printed pages 48–59

Questions about HDAC.

Selection, installation and care for this product range.

What is the difference between HDAC30 and HDAC30A?

HDAC30 is a three-piece HDAF30 + HDAR30 + HDAL30 combination. HDAC30A is a two-piece HDAW30 + HDAL30 combination. Both perform filtration, regulation and lubrication, but the physical layout and drawings differ. Confirm the full ordering code and available installation space.

Does 40 L/min describe the maximum flow of HDAC30?

No. It is the catalogue minimum oil-mist flow for the 30-size lubricator. The corresponding thresholds are 15 L/min for size 20 and 50 L/min for size 40. Ask XMC to check supply capacity at the operating pressure and permitted pressure drop.

Which filter grades and pressure range are listed?

The reviewed HDAC tables list 25 µm standard filtration, with 5 µm and 50 µm options, and a 0.05 to 0.85 MPa pressure regulating range. Maximum working pressure is 1.0 MPa. Confirm the element and complete assembly specified on the quotation.

What should I send for an HDAC quotation?

Provide two-piece or three-piece layout, body size, port and thread, minimum and peak flow, inlet and outlet pressure, lubrication requirement, filtration grade, drain arrangement, gauge preference and quantity. Include a mounting drawing or existing model when replacing an installed unit.

One series.
One document.

Download the catalogue pages for this series, including ordering references, specifications and available dimension drawings. Keep the original-resolution PDF with your project documents.

SeriesHDAC
SourcePrinted pages 48–59
FilePDF · 7.3 MB
Download HDAC PDF

Plan your order.

Share your model, quantity and destination with XMC to confirm the supply arrangement.

All service policies
Order quantity
XMC has not set a general minimum order quantity. Share the model and quantity you need so the team can confirm availability and a quotation.
Samples and customization
Paid samples are available. Customization can cover specifications, packaging and branding, subject to review of your requirements.
Dispatch and lead times
Core products can dispatch from the factory within 24 hours when available from stock. A 24/48-hour express service is available for selected products and regions only. Confirm stock, service availability and your order-specific dispatch schedule with XMC. Dispatch time is not the arrival date.
Warranty
The one-year warranty starts when the product is delivered to the location specified by the customer. Confirm the applicable warranty terms with your quotation.

Make it fit your application.

Share your operating conditions, installation space and expected quantity. Your selected reference will be included in the inquiry form.

Start a technical conversation

Explore the air preparation range.

Continue browsing components in this product family.